Evaluation of Cable Force Changes Effects on Cable Stayed Bridge

Theint Theint Thu Soe, San Yu Khaing

Abstract


The proposed bridge, which is cable stayed bridge crosses the Hlaing River that flows through Western Yangon. It was completed in 2000 and is currently used to connect Insein Township with Hlaing Tharyar Township. It has the 20 years’ service life. It requires the inspection and the evaluation of the real condition of the structure. As cable element plays an important role in cable structures, evaluation of the real state of the stay cable is one of the main focuses of the cable stayed bridge. Firstly, in the research work all cables are inspected to evaluate the current condition of the cables with included visual inspection and vibration-based cable force measurement method. With the help of static and moving load analysis, the effect of force change cables in which the successive force changes are considered, and the possible cable loss effect on the structural behavior of the bridge are also investigated. The finite element model of the cable stayed bridge is developed based on the geometric shape and material properties from MOC and is modelled with finite element software MIDAS Civil. The tension forces obtained by inspection over years (2000 to 2018) using vibration-based measurements method are compared with the measured intact cable forces. According to the results of the data analysis, it is observed that the cables force variations of the seven cables are abnormal conditions. In order to evaluate the condition of a bridge effected by cable force variation, the two parameters are considered; percentage increase in tension stress of all cables and percentage increase in deflection of the deck. The present study describes the structural response of the bridge in order to evaluate the actual safety of the bridge with abnormal force change cables, and also examines the consequences of one cable failure.

 

Doi: 10.28991/cej-2020-03091609

Full Text: PDF


Keywords


Cable Stayed Bridge; Inspection; Cable Force Change; Parameters; Evaluate.

References


Gimsing, Niels J., and Christos T. Georgakis. “Cable Supported Bridges” Technical University of Denmark, Lyngby, Denmark (December 23, 2011). doi:10.1002/9781119978237.

Khaing, Thinzar, Yu Yu Kyi Win, and Nyan Myint Kyaw. “Study on Rust Characterization and Prediction of Atmospheric Corrosion Rates for Structural Steels in Yangon (Myanmar).” IPTEK Journal of Proceedings Series 3, no. 6 (December 31, 2017). doi:10.12962/j23546026.y2017i6.3246.

H. M. Irvine. “Cable Structures.” Dover Publications. New York. NY. USA. (1991).

Xiang, Yang. "Static and Dynamic Analyses of a Long-Span Cable-Stayed Bridge with Corroded Cables." PhD diss., Université d'Ottawa/University of Ottawa, 2018. doi:10.20381/ruor-22699.

Ministry of Public Works and Transport. “Bridge Inspection Manual.” Road Infrastructure Department. February. (2018).

Mellier, Erik, Stephane Joye, and Vincent Maillet. “High Level Engineering for Stay Cable Replacement.” IABSE Symposium Report 96, no. 6 (January 1, 2009): 230–239. doi:10.2749/222137809796088224.

H. Wu, Y. Xiang, and Y. Li. “Research on Safety Evaluation of Large Span Cable Stayed Bridge.” China Municipal Engineering, Chinese, (2006).

Gang-Jun, Zhai, Yang Ying, and Bao Hong-Chen. "Study on Safety Evaluation of Cable-stayed Bridge Based on Inspection of the Main Span Cables' Tension." In 2013 Third International Conference on Intelligent System Design and Engineering Applications, pp. 1352-1354. IEEE, 2013. doi:10.1109/isdea.2012.320.

Zhang, Guanyong, Zhijun Zhang, and Chad Ficher. “Structural Health Monitoring of a Long-Span Cable-Stayed Bridge.” Journal of Intelligent Material Systems and Structures 18, no. 8 (March 29, 2007): 835–843. doi:10.1177/1045389x06074568.

Olamigoke, O, G Parke, and M Imam. “Effect of Cable Corrosion on the Structural Response of Cable-Stayed Bridges.” Multi-Span Large Bridges (June 9, 2015): 927–936. doi:10.1201/b18567-118.

Volkmar, Fred R., and Fred R. Volkmar, eds. Encyclopedia of Autism Spectrum Disorders. New York, NY: Springer, (2013).

Tabatabai, Habib. Inspection and maintenance of bridge stay cable systems: A synthesis of highway practice. Vol. 353. Transportation Research Board, (2005).

Dan, Dan-Hui, Yi-Ming Zhao, Tong Yang, and Xing-Fei Yan. "Health condition evaluation of cable-stayed bridge driven by dissimilarity measures of grouped cable forces." International Journal of Distributed Sensor Networks (2013). doi:10.1155/2013/818967.

Ataei, Hossein, Mohammadhossein Mamaghani, and Riyad S. Aboutaha. “Finite Element Analysis of Cable-Stayed Strands’ Failure Due to Fire.” Forensic Engineering 2015 (November 9, 2015). doi:10.1061/9780784479711.072.

T. Hopwood II., J.H. Havens. “Corrosion of Cable Suspension Bridges.” University of Kentucky (May, 1984). doi:10.13023/ktc.rr.1984.14.

J. M. Kulicki, Z. Prucz, D, F. Sorgenfre|, and D. R. Mertz. “Guidelines for Evaluating Corrosion Effects in Existing Steel Bridges.” Mod¡eski and Masters. Harrisburg. Pennsylvania, (December,1990). (Cat. N0.90-71850).

European Committee for Standardisation. “Eurocode 3 - Design of steel structures - Part 1-11: Design ofstructures with tension components.” (October 2006). doi:10.3403/BSEN1993.

Lemaitre, Jean. “A Course on Damage Mechanics” (1992). doi:10.1007/978-3-662-02761-5.

Janiand, Harshil, and Jignesh Amin. "Analysis of cable stayed bridge under cable loss." International Journal of Bridge Engineering 5, no. 1 (2017): 61-78.


Full Text: PDF

DOI: 10.28991/cej-2020-03091609

Refbacks

  • There are currently no refbacks.




Copyright (c) 2020 theint theintthu soe

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
x