Limitations on ACI Code Minimum Thickness Requirements for Flat Slab

Bilal Ismaeel Abd Al-Zahra, Maitham Alwash, Ameer Baiee, Ali A. Shubbar

Abstract


Reinforced concrete two-way flat slabs are considered one of the most used systems in the construction of commercial buildings due to the ease of construction and suitability for electrical and mechanical paths. Long-term deflection is an essential parameter in controlling the behavior of this slab system, especially with long spans. Therefore, this study is devoted to investigating the validation of the ACI 318-19 Code long-term deflection limitations of a wide range of span lengths of two-way flat slabs with and without drop panels. The first part of the study includes nonlinear finite element analysis of 63 flat slabs without drops and 63 flat slabs with drops using the SAFE commercial software. The investigated parameters consist of the span length (4, 5, 6, 7, 8, 9, and 10m), compressive strength of concrete (21, 35, and 49 MPa), the magnitude of live load (1.5, 3, and 4.5 kN/m2), and the drop thickness (0.25tslab, 0.5tslab, and 0.75tslab). In addition, the maximum crack width at the top and bottom are determined and compared with the limitations of the ACI 224R-08. The second part of this research proposes modifications to the minimum slab thickness that satisfy the permissible deflection. It was found, for flat slabs without drops, the increase in concrete compressive strength from 21MPa to 49MPa decreases the average long-term deflection by (56, 53, 50, 44, 39, 33 and 31%) for spans (4, 5, 6, 7, 8, 9, and 10 m) respectively. In flat slab with drop panel, it was found that varying drop panel thickness t2 from 0.25  to 0.75  decreases the average long-term deflection by (45, 41, 39, 35, 31, 28 and 25%) for span lengths (4, 5, 6, 7, 8, 9 and 10 m) respectively. Limitations of the minimum thickness of flat slab were proposed to vary from Ln/30 to Ln/19.9 for a flat slab without a drop panel and from Ln/33 to Ln/21.2 for a flat slab with drop panel. These limitations demonstrated high consistency with the results of Scanlon and Lee's unified equation for determining the minimum thickness of slab with and without drop panels.

 

Doi: 10.28991/cej-2021-03091769

Full Text: PDF


Keywords


Long-term Deflection; Allowable Deflection; Flat Slab; Drop Panel Thickness; Concrete Compressive Strength; Crack width; Span Length.

References


Fanella, David. “Reinforced Concrete Structures: Analysis and Design.” McGraw-Hill Companies, (2016).

McCormac, Jack C., and Russell H. Brown. “Design of Reinforced Concrete.” John Wiley & Sons, (2015).

Darwin, David, Charles William Dolan, and Arthur H. Nilson. Design of concrete structures. Vol. 2. New York, NY, USA:: McGraw-Hill Education, (2016).

ACI Committe 318, “Building Code Requirements for Structural Concrete and Commentary (ACI 318-19),” Farmington Hill, MI, (2019).

Canadian Standards Association, “Design of Concrete Structures for Buildings (CSA A23.3-04),” Rexdale, (2004).

Standards Association of Australia. AS 3600: Concrete Structures.” North Sydney 2009 (2009): 1–108.

European Committee for Standardization CEN, “Eurocode 2: Design of concrete structures -Part 1-1: General rules and rules for buildings (EN 1992-1-1:2004),” Brussels, (2004).

Setareh, Mehdi, and Robert Darvas. “Concrete Structures” (2017). doi:10.1007/978-3-319-24115-9.

Ashraf, Syed Mehdi. Practical Design of Reinforced Concrete Buildings. Practical Design of Reinforced Concrete Buildings. CRC Press, (2017). doi:10.1201/b22298.

Gilbert, R. I. “The Serviceability Limit States in Reinforced Concrete Design.” Procedia Engineering 14 (2011): 385–95. doi:10.1016/j.proeng.2011.07.048.

Pack, Lonnie. Australian Guidebook for Structural Engineers. Australian Guidebook for Structural Engineers. CRC Press, (2017). doi:10.4324/9781315197326.

Tošić, Nikola, Nenad Pecić, Mauro Poliotti, Antonio Marí, Lluis Torres, and Jelena Dragaš. “Extension of the ζ-Method for Calculating Deflections of Two-Way Slabs Based on Linear Elastic Finite Element Analysis.” Structural Concrete 22, no. 3 (2021): 1652–70. doi:10.1002/suco.202000558.

Hossain, Tahsin Reza, Salah Uddin Ahmed, and Mohammed Saiful Alam Siddiquee. “Prediction of Short- and Long-Term Deflections of Reinforced Concrete Flat Plates Using Artificial Neural Network.” Journal of Civil Engineering (IEB) 47, no. 2 (2019): 167–77.

Gilbert, R. I. “Deflection Control of Slabs Using Allowable Span To Depth Ratios.” Journal of the American Concrete Institute 82, no. 1 (1985): 67–72. doi:10.14359/10316.

Scanlon, Andrew, and Young Hak Lee. “Unified Span-to-Depth Ratio Equation for Nonprestressed Concrete Beams and Slabs.” ACI Structural Journal 103, no. 1 (2006): 142–48. doi:10.14359/15095.

Caldentey, Alejandro Pérez, Javier Mendoza Cembranos, and Hugo Corres Peiretti. “Slenderness Limits for Deflection Control: A New Formulation for Flexural Reinforced Concrete Elements.” Structural Concrete 18, no. 1 (2017): 118–27. doi:10.1002/suco.201600062.

K. A. Ahmat, "Probabilistic Assessment of ACI 318 Minimum Thickness Requirements for Two-way Slabs", MSc Thesis, University of Sharjah, Sharjah - United Arab Emirates, (2017).

Fahmi, Mereen H., and Ayad Z. Saber. “Modified Minimum Depth-Span Ratio of Beams and Slabs.” International Journal of Emerging Trends in Engineering Research 8, no. 9 (2020): 5571–80. doi:10.30534/ijeter/2020/107892020.

Vollum, R. L., and T. R. Hossain. “Are Existing Span-to-Depth Rules Conservative for Flat Slabs?” Magazine of Concrete Research 54, no. 6 (2002): 411–21. doi:10.1680/macr.2002.54.6.411.

Lee, Young Hak, and Andrew Scanion. “Comparison of One- And Two-Way Slab Minimum Thickness Provisions in Building Codes and Standards.” ACI Structural Journal 107, no. 2 (2010): 157–63. doi:10.14359/51663531.

Bertero, Raul, and Agustin Bertero. “Statistical Evaluation of Minimum Thickness Provisions for Slab Deflection Control.” ACI Structural Journal 116, no. 5 (2019): 301–2. doi:10.14359/51720209.

Hasan, S A, and B O Taha. “Aspect Ratio Consideration in Flat Plate Concrete Slab Deflection.” Zanco Journal of Pure and Applied Sciences 32, no. 5 (2020). doi:10.21271/zjpas.32.5.6.

Sanabra-Loewe, Marc, Joaquín Capellà-Llovera, Sandra Ramírez-Anaya, and Ester Pujadas-Gispert. “A Path to More Versatile Code Provisions for Slab Deflection Control.” Proceedings of the Institution of Civil Engineers - Structures and Buildings (April 15, 2021): 1–15. doi:10.1680/jstbu.20.00205.

Al-Nu’man, B S, and C S Abdullah. “Investigation of a Developed Deflection Control Model of Reinforced Concrete Two Way Slab Systems.” Eurasian Journal of Science and Engineering 4, no. 1 (2018): 18–31,. doi:10.23918/eajse.v4i1sip18.

Santos, José, and António Abel Henriques. “Span-to-Depth Ratio Limits for RC Continuous Beams and Slabs Based on MC2010 and EC2 Ductility and Deflection Requirements.” Engineering Structures 228 (2021): 111565. doi:10.1016/j.engstruct.2020.111565.

Portland Cement Association. Notes on ACI 318-11. Illinois: Portland Cement Association, (2013).

“ACI Committe 224, “Control of Cracking in Concrete Structures (ACI 224R-08).” Farmington Hill, MI, (2008).


Full Text: PDF

DOI: 10.28991/cej-2021-03091769

Refbacks

  • There are currently no refbacks.




Copyright (c) 2021 Bilal Ismaeel Abd Al-Zahra, Maitham Alwash, Ameer Baiee, Ali Shubbar

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
x
Message